KRF Heavy Duty Standard Model Dry Pump

KRF70 / KRF110

Continuous Operating Vacuum : 60 kPa or less (V/VB)
80 kPa or less (VH / VBH)
Continuous Operating Pressure : 60 kPa or less (B/VB)
70 kPa or less (BH)
80 kPa or less (VBH)
Flow Rate : 1350 to 2200 L/min (60 Hz)
  • Safe and Environmentally Conscious
  • Quiet Operation
  • Long Life

Description

Specifications :

Model KRF70- V-01B V-04B ※4 VH-01B VH-04B ※4
Designed Pumping Capacity(50/60 Hz) ※1 L/min 1130/1350
Ultimate Vacuum ※2 kPa (min.) 90
Continuous Operating Vacuum ※3 kPa (max.) 60 80
Continuous Operating Pressure ※3 kPa (max.)
Piping Connection Size Rc 1
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
Noise level (50/60 Hz) ※5 dB 67/68 73/74
Motor kW 2.2
Mass kg 94
Model KRF70- V-01B V-04B ※4 VH-01B VH-04B ※4
Designed Pumping Capacity(50/60 Hz) ※1 L/min 1130/1350
Ultimate Vacuum ※2 kPa (min.) 90
Continuous Operating Vacuum ※3 kPa (max.) 60 80
Continuous Operating Pressure ※3 kPa (max.)
Piping Connection Size Rc 1
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
Noise level (50/60 Hz) ※5 dB 67/68 73/74
Motor kW 2.2
Mass kg 94
Model KRF70- VB-01B VB-04B ※4 VBH-01B VBH-04B ※4
Designed Pumping Capacity (50/60 Hz) ※1 L/min 1130/1350
Ultimate Vacuum ※2 kPa (min.)
Continuous Operating Vacuum ※3 kPa (max.) Total: 60 or lower Total: 80 or lower
Continuous Operating Pressure ※3 kPa (max.)
Piping Connection Size Rc 1
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
Noise Level (50/60 Hz) ※5 dB 67/68 73/74
Motor kW 2.2
Mass kg 94
Model KRF110- V-01B V-04B ※4 B-01B B-04B ※4
Designed Pumping Capacity (50/60 Hz) ※1 L/min 1850/2200
Ultimate Vacuum ※2 kPa (min.) 90
Continuous Operating Vacuum ※3 kPa (max.) 60
Continuous Operating Pressure ※3 kPa (max.) 60
Piping Connection Size Rc 1 1/4
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 16.6/
15.6、14.8、14.8
8.5、8.3、8.3/
7.8、7.4、7.4
16.6/
15.6、14.8、14.8
8.5、8.3、8.3/
7.8、7.4、7.4
Noise level (50/60 Hz) ※5 dB 74/75 76/77
Motor kW 3.7
Mass kg 131
Model KRF110- VB-01B VB-04B ※4
Designed Pumping Capacity (50/60 Hz) ※1 L/min 1850/2200
Ultimate Vacuum ※2 kPa (min.)
Continuous Operating Vacuum ※3 kPa (max.) Total: 60 or lower
Continuous Operating Pressure ※3 kPa (max.)
Piping Connection Size Rc 1 1/4
Voltage (50/60 Hz) V Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400, 415/
Three-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 16.6/
15.6、14.8、14.8
8.5、8.3、8.3/
7.8、7.4、7.4
Noise level (50/60 Hz) ※5 dB 74/75
Motor kW 3.7
Mass kg 131
  1. Designed pumping capacity. Theoretical value calculated from cylinder volume. Refer to “Performance Data” for actual flow rate.
  2. Operation not allowed at ultimate vacuum.For model selection purposes only.
  3. Operable range of vacuum (pressure).
  4. “04” models are special order items.
  5. Operating noise measured on a new pump with an ORION recommended motor running at the recommended vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
  • Operating environment (inlet air) conditions: air temp: 0 to 40 ℃, humidity: normal level (65±20%).
  • Allowable intermittent power supply voltage fluctuation range is ±10%, and the allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
  • Please install an overload protection device (such as a thermal relay).
  • See specifications sheet for further details.

External Dimension (Units: mm) :

Performance Date :