CBXP

Continuous Operating Vacuum : 60 kPa or less
(CBXP□A-VB-02B/VV-02B)
(CBXP□B-VB-02B, 03B/VV-02B, 03B)
Continuous Operating Pressure : 80 kPa or less
(CBXP□A-VB-02B)
70 kPa or less
(CBXP□B-VB-02B, 03B)
60 kPa or less
(CBXP□A-BB-02B, CBXP□B-BB-02B, 03B)
Flow Rate : 1115 to 2200 L/min (60 Hz)
  • Lower operating noise
  • Improved maintenance characteristics

Description

Specifications :

Model CBXP ※1 6070A-VB-02B 8080B-VB-02B, 03B 90110B-VB-02B, 03B
Designed Pumping Capacity (50/60 Hz) ※2 L/min Pump 1 (V):935/1115
Pump 2 (B):1160/1380
Pump 1 (V):1315/1545
Pump 2 (B):1370/1650
Pump 1 (V):1500/1800
Pump 2 (B):1850/2200
Continuous Operating Vacuum ※3 kPa (min.) Pump 1: 60
Continuous Operating Pressure ※3 kPa (min.) Pump 2: 80 Pump 2: 70
Piping Connection Size Intake Side:R1
Exhaust Side:R1
Intake Side:R1
Exhaust Side:R1 1/4
Intake Side:R1 1/4
Exhaust Side:R1 1/4
Voltage (50/60 Hz) V Three-phase 200 / three-phase 200
Standard Motor Current Rating (50/60 Hz) A 22.6/20.8 29.6/28
Noise Level (50/60 Hz) ※4 dB 73/76 76/78 79/81
Motor kW 5.5 7.5
Mass kg 177 260 305
Model CBXP ※1 6060A-VV-02B 8080B-VV-02B, 03B 9090B-VV-02B, 03B 110110B-VV-02B, 03B
Designed Pumping Capacity (50/60 Hz) ※2 L/min Pump 1 (V): 935/1115
Pump 2 (V): 935/1115
Pump 1 (V):1315/1545
Pump 2 (V):1315/1545
Pump 1 (V):1500/1800
Pump 2 (V):1500/1800
Pump 1 (V):1850/2200
Pump 2 (V):1850/2200
Continuous Operating Vacuum ※3 kPa (min.) Pump 1: 60, Pump 2: 60
Continuous Operating Pressure ※3 kPa (min.)
Piping Connection Size Intake Side: R1 Exhaust Side: R1 Intake Side:R1 1/4, Exhaust Side:R1 1/4
Voltage (50/60 Hz) V 3-phase 200 / 3-phase 200
Standard Motor Current Rating (50/60 Hz) A 15.4/14.4 22.6/20.8 29.6/28
Noise Level (50/60 Hz) ※4 dB 72/73 72/74 75/77 77/79
Motor kW 3.7 5.5 7.5
Mass kg 147 192 272 280
Model CBXP ※1 6060A-BB-02B 8080B-BB-02B, 03B 9090B-BB-02B, 03B 110110B-BB-02B, 03B
Designed Pumping Capacity (50/60 Hz) ※2 L/min Pump 1 (B): 935/1115
Pump 2 (B): 935/1115
Pump 1 (B):1315/1545
Pump 2 (B):1315/1545
Pump 1 (B):1500/1800
Pump 2 (B):1500/1800
Pump 1 (B):1850/2200
Pump 2 (B):1850/2200
Continuous Operating Vacuum ※3 kPa (min.)
Continuous Operating Pressure ※3 kPa (min.) Pump 1: 60, Pump 2: 60
Piping Connection Size Intake Side: R1 Exhaust Side: R1 Intake Side:R1 1/4, Exhaust Side:R1 1/4
Voltage (50/60 Hz) V 3-phase 200 / 3-phase 200
Standard Motor Current Rating (50/60 Hz) A 15.4/14.4 22.6/20.8 29.6/28
Noise Level (50/60 Hz) ※4 dB 76/79 74/78 78/80 80/81
Motor kW 3.7 5.5 7.5
Mass kg 147 192 272 280
  1. CBXP□A-□-02B and CBXP□B-□-02B models are equipped with casters. CBXP□B-□-03 models are equipped with casters and an hour meter.
  2. Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to “Performance Data” for actual flow rate.
  3. Operable range of vacuum (pressure).
  4. Operating noise measured on a new pump with an ORION recommended motor running at normal vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
  • Operating environment (inlet air conditions: air temp: 0 to 40℃, humidity: normal levels (65±20%).
  • Allowable intermittent power supply voltage fluctuation range is +10% of the specified voltage, allowable sustained supply voltage fluctuation range is 5% of the specified voltage.
  • Please install an overload protection device (such as a thermal relay).
  • To ensure proper pump ventilation, make sure there is at least 300 mm clearance between the pump and walls, and at least 1,000 mm clearance between the top of the pump and the ceiling.
  • In order to allow for pump maintenance, maintain an open space at least 500 mm from the front face of the unit.

External Dimension (Units: mm) :

Performance Date :

CBXP□□□□A-VB-02B、CBXP□□□□B-VB-02B,03B

Vacuum (V)

Blower (B)

CBXP□□□□A-VV-02B、CBXP□□□□B-VV-02B,03B

Vacuum (V) (Pump1)

Vacuum (V) (Pump2)

CBXP□□□□A-BB-02B、CBXP□□□□B-BB-02B,03B

Blower (B) (Pump1)

Blower (B) (Pump2)